Honeywell FC-PUIO01 is a SIL3 rated universal safety I/O module for Honeywell Safety Manager SC safety instrumented system.
Send Inquiry

Products Description

Honeywell FC-PUIO01 Safety I/O Module in stock


Honeywell FC-PUIO01 is a SIL3 rated universal safety I/O module for Honeywell Safety Manager SC safety instrumented system. It supports software configurable analog and digital channels, integrating multiple signal types for emergency shutdown and safety interlock control.


Honeywell   FC-PUIO01(1).jpeg

This safety module matches terminal base FC-TUIO011, with channel-to-channel galvanic isolation and built-in fault diagnosis. It is widely used as maintenance spare in petrochemical, refinery and natural gas SIS safety control cabinets.


Honeywell   FC-PUIO01(2).jpeg

Data Parameters


  • 1. Brand: Honeywell.

  • 2. Model: FC-PUIO01.

  • 3. Product Type: SIL3 Universal Safety I/O Module.

  • 4. Application: Safety Manager SC SIS safety instrument system.

  • 5. Feature: Configurable AI/AO/DI/DO, SIL3, channel isolation, self-diagnosis.

  • 6. Characteristic: Safety certified design, 2.5kV isolation, fault detection per channel.

  • 7. Communication: Backplane safety bus with Safety Manager SC controller.

  • 8. Package: Safety I/O module, FC-TUIO011 terminal base sold separately.

  • 9. Mounting: Safety rack slot installation inside SIS control cabinet.

  • 10. Operating Temperature: -40℃ ~ +70℃.

Core Functions


  • 1. Collect analog 4-20mA and digital status signals from field safety transmitters and switches.

  • 2. Output safety control signals to ESD valves, trip relays and emergency shutdown actuators.

  • 3. Execute continuous channel diagnosis, detect wiring short, open circuit and internal hardware fault.

  • 4. Transmit safety alarm and trip event data to Safety Manager SC host controller.

  • 5. Meet SIL3 safety integrity requirement for process emergency interlock protection.

Application Scenarios


  • 1. Petrochemical plant SIS ESD safety cabinet spare replacement and maintenance.

  • 2. Oil refinery and natural gas pipeline emergency shutdown control renovation project.

  • 3. Chemical hazardous area safety instrument interlock and protection cabinet.

  • 4. Old Honeywell Safety Manager SC SIS cabinet upgrade and transformation.

  • 5. Energy and offshore platform safety control spare inventory backup.

FAQ


  • 1. Q: What is Honeywell FC-PUIO01?
        A: It is SIL3 universal safety I/O card for Honeywell Safety Manager SC SIS system.

  • 2. Q: What is the matching IOTA base?
        A: The corresponding terminal base model is FC-TUIO011.

  • 3. Q: Can it be used on Experion PKS C300 DCS?
        A: No, it belongs to SIS safety system hardware, not for normal DCS control.